LOW BATTERY INDICATION
SIZE (HxWxL)
WEIGHT
“
”appears on the display
31.5mm×91mm×189mm
310g(including battery)
4.2 DC VOLTAGE
Range Resolution Accuracy
200mV
2V
20V
200V
1000V
0.1mv
1mV
10mV
0.1V
1V
±0.5% of rdg ± 1 digit
±0.5% of rdg ± 1 digit
±0.5% of rdg ± 1 digit
±0.5% of rdg ± 1 digit
±0.8% of rdg ± 2 digits
Input impedance:10MΩ
-16-
4.3 AC VOLTAGE
Range Resolution Accuracy
200mV
2V
20V
200V
700V
0.1mv
1mV
10mV
0.1V
1V
±1.2% of rdg ± 3 digits
±0.8% of rdg ± 3 digits
±0.8% of rdg ± 3 digits
±0.8% of rdg ± 3 digits
±1.2% of rdg ± 3 digits
Input impedance: 10MΩ
Frequency Range: 40Hz to 400Hz
Response: Average, calibrated in rms of sine wave
-17-
4.4 DC CURRENT
Range Resolution Accuracy Burden Voltage
2mA
20mA
200mA
10A
1μA
10μA
0.1mA
10mA
±0.8% of rdg ± 1 digit
±0.8% of rdg ± 1 digit
±1.5% of rdg ± 1 digit
±2.0% of rdg ± 5 digit
110mV/mA
15mV/mA
5.0mV/mA
0.03V/A
-18-
4.5 AC CURRENT
Range Resolution Accuracy Burden Voltage
2mA
20mA
200mA
10A
1μA
10μA
0.1mA
10mA
±1.0% of rdg ± 3 digits
±1.0% of rdg ± 3 digits
±1.8% of rdg ± 3 digits
±3.0% of rdg ± 7 digits
110mV/mA
15mV/mA
5.0mV/mA
0.03V/A
Frequency Range: 40Hz to 400Hz
Response:Average, Calibrated in rms of sine wave
-19-